A&D Weighing HW-1200KGV3 User Manual
Page 70
Page 68
HV-G/HW-G Series
17. Options
17.3. RS-422/ RS-485 / Relay Output (OP-04)
Replacing with the standard RS-232C interface, the RS-422/ RS-485 interface can
connect up to 16 scales and control them from a computer.
The RS-422/ RS-485 interface has the following two modes.
Stream mode
Outputs data continuously.
Command mode Controls the scale using commands from a computer.
To use the RS-422/ RS-485 interface, set the parameters of the "Baud rate (
f4
)",
“Address (
f11
)", "Output mode (
f5
)" and " Format (
f15
)" in the function table.
Transmission system
EIA RS-422/ RS-485
Transmission
Asynchronous, bi-directional, half-duplex
Data format
Baud rate
2400, 4800, 9600 bps
Data
7
bits
Parity
1 bit, Even
Start bit
1 bit
Stop bit
1 bit
Code
ASCII
Terminator
CR LF (CR: 0Dh, LF: 0Ah)
Address
01 to 99
Address parameter (
f11
) of function table.
Relay
Solid-state-relay
Maximum voltage
50V DC
Maximum current
100mA DC
Maximum resistance
8
Ω
Adaptable connector
TM:BLA9 (of accessory)
Pin
connections
Pin No. Signal name Direction
Description
A
1
SDA
Output
RS-422/485 transmission A terminal
A
2
SDB
Output
RS-422/485 transmission B terminal
A
3
RDA
Input
RS-422/485 receive A terminal
A
4
RDB
Input
RS-422/485 receive B terminal
A
5 TRM
-
120
Ω terminator
A
6
HI
Output
Relay output of HI
A
7
OK
Output
Relay output of OK
A
8
LO
Output
Relay output of LO
A
9
COM
-
Relay common terminal
A