Preparation (setting parameters), A a a – A&D Weighing HW-1200KGV3 User Manual
Page 36

Page 34
HV-G/HW-G Series
10. Accumulation Function
Function table
Description
A
f8 3
When the display is a positive stable value and not nearly-zero, the
scale accumulates the data automatically. The next accumulation
can be performed after the display becomes nearly-zero or a
negative value.
f8 4
When the display is a stable value and not nearly-zero, the scale
accumulates the data automatically. The next accumulation can be
performed after the display becomes nearly-zero.
Use
Recording the number and mass of articles removed from
the pan. (Place the articles on the pan. Press the
TARE
key
at each removal.)
A
A
A
A
A
f8 5
At each end of the full/dribble batch function, the scale accumulates
the data automatically.
Use
Packaging articles like a powder, it is used for recording the
number of bags and the total mass.
A
A
A
10.1. Preparation (Setting Parameters)
Step 1 Turn off the display.
Press and hold the
ZERO
key and press the
ON/OFF
key. The function table is displayed.
Step 2 Press the
ENTER
key to display an item of the
accumulation function (
f8
).
Step 3 Select a parameter of the accumulation function
(
f8 1
to
f8 4
) with the
∧
key.
Step 4 Press the
ENTER
key and the
F
key to display
end . Press the
ENTER
key to return to the
normal weighing mode.