Preparation (setting parameters), Caution – A&D Weighing HW-1200KGV3 User Manual
Page 47

HV-G/HW-G Series
Page 45
13. Simple Batch Function
Caution
The parameters of the upper limit value (HI) and a final value (HI) use the
same memory. The parameters of the lower limit value (LO) and the
preliminary value (OK) use the same memory.
The upper/lower comparator function, the simple batch function and the
full/dribble batch function can not be used at the same time because these
parameters use the common memory.
13.1. Preparation (Setting Parameters)
Step 1 Turn off the display.
Press and hold the
ZERO
key and press the
ON/OFF
key.
The function table is displayed.
Step 2 Press the
ENTER
key to display an item of the
comparator function (
f6
).
Step 3 Select a parameter of the simple batch function
(
f6 8
) with the
∧
key.
Step 4 Press the
ENTER
key and the
F
key to display end .
Step 5 Press the
ENTER
key to return to the normal weighing
mode.