Connection and wiring – KEYENCE IG Series User Manual
Page 4
4
z When mounting the sensor head from the lateral side
Mounting from the sensor side
Mount using the commercially available screws (IG-010: M3, IG-028: M4)
Tightening torque: 1.6 N·m or less
Mounting from the jig side
Mount using the commercially available screws (IG-010: M4, IG-028: M5, length: board
thickness + 5 mm or less).
Tightening torque: 1.6 N·m or less
z When mounting from the bottom side
Mount using the commercially available screws (M3, length(IG-010): board thickness + 4
mm or less, length(IG-028): board thickness + 5 mm or less).
Tightening torque: 1.6 N·m or less
z When the mounting bracket (IG-TB01/IG-TB02: optional) is used
1
Attach the mounting bracket to the sensor head.
Press the sensor head to the mounting bracket firmly and
mount with the hexagon socket head bolt (M3, length: 5
mm).
Tightening torque: 1.6 N·m or less
2
Mount the mounting bracket.
Use the commercially available hexagon socket head bolt (M4) to mount the mounting
bracket through its holes.
Connection and Wiring
Connecting the sensor head and amplifier
1
Attach the sensor head connection cables to the transmitter and receiver cables
respectively.
2
Attach the sensor head connection cable on the receiver side to the [R] connector of
amplifier.
Remove the lock cover of the
connector and insert it into the
connectors (R) of amplifier until a
clicking sound can be heard.
3
Attach the lock cover to the connector to secure the cable.
4
Attach the sensor head connection cable on the transmitter side to the [T] connector
of amplifier.
The connection procedure is the same as that for the receiver side.
IG-010
IG-028
IG-010
IG-028
IG-010
IG-028
IG-010
IG-028
IG-010
IG-028
Note
Tighten the connectors securely by hand.
If they are loose, the environment resistance IP67 cannot be guaranteed.
Note
When removing the sensor head connection cable, push the lock lever
and pull it out.
(1) Align the arrow position of the connector to insert.
(2) Rotate the connector screw to tighten.
The red O-ring is attached to the transmission
cable and the blue O-ring to the receiver cable.
Connect the sensor head connection cable with
red O-ring attached to the transmitter and
connect the sensor head connection cable with
the blue O-ring attached to the receiver.
Unlocked
Lock cover
Click
Down: R side
Right:
R side
Blue O-ring
DIN rail mount type
(IG-1000/IG-1050)
Panel mount type
(IG-1500/IG-1550)
Locked
Lock cover
Lock lever
Up: T side
Left:
T side
Red O-ring
DIN rail mount type
(IG-1000/IG-1050)
Panel mount type
(IG-1500/IG-1550)