3-6
DP-V1 Service
3-34
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -
Execu
ting Communi
cat
ion
3
121
Pin interval judgment mode or
pin diameter judgment mode:
Number of pins (BANK 1)
DINT
R/W
02
2 to 14
122
Specified edges interval
measurement mode: Edge
number 1 (BANK 2)
*19
DINT
R/W
+001
-100 to +100
123
Specified edges interval
measurement mode: Edge
number 2 (BANK 2)
*19
DINT
R/W
+002
-100 to +100
124
Pin interval judgment mode or
pin diameter judgment mode:
Number of pins (BANK 2)
DINT
R/W
02
2 to 14
125
Specified edges interval
measurement mode: Edge
number 1 (BANK 3)
*19
DINT
R/W
+001
-100 to +100
126
Specified edges interval
measurement mode: Edge
number 2 (BANK 3)
*19
DINT
R/W
+002
-100 to +100
127
Pin interval judgment mode or
pin diameter judgment mode:
Number of pins (BANK 3)
DINT
R/W
02
2 to 14
128
Group4 Entry count
DINT
R
31
129
Calculation function
DINT
R/W
0
0: Do not use calculation
function
1: Addition mode
2: Subtraction mode
3: 2-head mode
130
Measurement mode
DINT
R/W
0
0: Edge control/positioning mode
1: Outer diameter/width
measurement mode
2: Inner diameter/gap
measurement mode
3: Glass edge mode
4: Pin position measurement mode
5: Pin interval measurement mode
6: Pin diameter measurement mode
7: Specified edge interval
measurement mode
131
Measurement direction
DINT
R/W
0
0: Top
1: Bottom
132
Reserved for system
133
Averaging
*20
DINT
R/W
05
0:
hsp
1:
1 time
2:
2 times
3:
4 times
4:
8 times
5:
16 times
6:
32 times
7:
64 times
8:
128 times
9:
256 times
10: 512 times
11: 1024 times
12: 2048 times
13: 4096 times
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value