6 dp-v1 service, Execu ting communi cat ion – KEYENCE DL-PD1 User Manual
Page 49

3-6
DP-V1 Service
3-27
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -
Execu
ting Communi
cat
ion
3
32
DL-PD1 error state
Stores the DL-PD1 error
status.
2byte
WORD
R
bit0-4: Error code
bit5-15: 0 (Fixed)
33
Number of connectable
units
Stores the number of sensor
amplifiers connected to the
DL-PD1.
2byte
INT
R
0 to 15
34 to 63 Reserved for system
64
Error state
When the sensor amplifier is
in the error state, the
corresponding bit is set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
65
Warning status
When the sensor amplifier is
in the warning state, the
corresponding bit is set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
66
Comparator value property
When the sensor amplifier
comparator value is invalid or
exceeding the upper or lower
limit, the corresponding bit is
set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
67
Comparator value over
range
When the sensor amplifier
comparator value is
exceeding the upper limit, the
corresponding bit is set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
68
Comparator value under
range
When the sensor amplifier
comparator value is
exceeding the lower limit, the
corresponding bit is set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
69
Comparator value Invalid
When the edge output is ON,
the corresponding bit is set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
70 to 77 Reserved for system
78
Output 1
When the control output of
sensor amplifier is High, the
corresponding bit is set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
79
Output 2
When the control output of
sensor amplifier is Low, the
corresponding bit is set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
80
Output 3
When the control output of
sensor amplifier is Go, the
corresponding bit is set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
81
Output 4
When the edge output is ON,
the corresponding bit is set.
2byte
WORD
R
bit0
: Reserved for system
bit1
: Slot 1
:
bit15 : Slot 15
82 to 85 Reserved for system
Index
(DEC)
Function name
Description
Data
type
Attribute
Value