6 dp-v1 service, Execu ting communi cat ion – KEYENCE DL-PD1 User Manual
Page 55

3-6
DP-V1 Service
3-33
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (IG) -
Execu
ting Communi
cat
ion
3
84
LOW setting value (BANK 3)
*15
DINT
R
+02.000
-99.999 to +99.999
85
Shift target value (BANK 3)
*15
DINT
R
00.000
-99.999 to +99.999
86
Sensitivity setting (BANK 3)
DINT
R
1
0: Low sensitivity mode
1: Standard mode
2: High sensitivity mode
3: User defined
87
User binarize level (Bank 3)
DINT
R
25
10 to 90
88
User filter value (Bank 3)
DINT
R
09
03 to 50
89 to 95 Reserved for system
96
Group3 Entry Count
DINT
R
31
97
Keylock function
DINT
R/W
0
0: Unlock
1: Key lock
98
Bank function
*16
DINT
R
0
0 to 3: Currently active bank
W
0
0: Switched to bank 0
1: Switched to bank 1
2: Switched to bank 2
3: Switched to bank 3
99
Timing input request
*17
DINT
R/W
0
0: Timing input OFF
1: Timing input ON
100
Laser emission stop request
*17
DINT
R/W
0
0: Laser emission stop input
OFF (laser emitting)
1: Laser emission stop input
ON (laser emission stopped)
101 to
103
Reserved for system
104
Sub display's screen
DINT
R/W
0
0: R.V. value display screen
1: Analog output screen
2: HIGH setting screen
3: LOW setting screen
4: Shift target value setting screen
5: Calculation value display screen
105
System parameter
*12
DINT
R/W
00
0 to 15
106
Tolerance setting width
*18
DINT
R/W
00.100
00.000 to 99.999
107
Calibration Function
DINT
R/W
0
0: Standard
1: User setting
108
Calibration function SET1
DINT
R/W
00.000
-99.999 to +99.999
109
Calibration function SET2
DINT
R/W
+05.000
-99.999 to +99.999
110 to
115
Reserved for system
116
Specified edges interval
measurement mode: Edge
number 1 (BANK 0)
*19
DINT
R/W
+001
-100 to +100
117
Specified edges interval
measurement mode: Edge
number 2 (BANK 0)
*19
DINT
R/W
+002
-100 to +100
118
Pin interval judgment mode or
pin diameter judgment mode:
Number of pins (BANK 0)
DINT
R/W
02
2 to 14
119
Specified edges interval
measurement mode: Edge
number 1 (BANK 1)
*19
DINT
R/W
+001
-100 to +100
120
Specified edges interval
measurement mode: Edge
number 2 (BANK 1)
*19
DINT
R/W
+002
-100 to +100
Index
(DEC)
Function name
Description
Data
type
Attribute
Default
value
Value