9

serVICe and maInTenanCe

nOTe: any servicing dealer attempting a

warranty repair must have prior

approval before conducting main-

tenance of a Hydro-Gear® product

unless the servicing dealer is a cur-

rent authorized Hydro-Gear service

Center.

eXTernal maInTenanCe

Regular external maintenance of the T2

®

should

include the following:
1 . Check the vehicle operator’s manual for

the recommended load ratings . Insure

the current application does not exceed

load rating .

2 . Check oil level in accordance with Figure 3

Page 10 .

3 . Inspect the vehicle drive belt, idler pulley(s),

and idler spring(s) . Insure that no belt

slippage can occur . Slippage can cause low

input speed to the transmission .

4 . Inspect the transmission cooling fan for

broken or distorted blades and remove any

obstructions (grass clippings, leaves, dirt,

etc .) .

5 . Inspect the axle parking brake and vehicle

linkage to insure proper actuation and

adjustment of the parking brake .

6 . Inspect the vehicle control linkage to the

directional control arm on transaxle . Also,

insure the control arm is securely fastened

to the trunnion arm of the transaxle .

7 . Inspect the bypass mechanism on the

transaxle and vehicle linkage to insure it

actuates and releases fully .

serVICe and maInTenanCe

prOCedures

All the service and maintenance procedures

presented on the following pages can be

performed while the T2 is mounted on the

vehicle . Any repair procedures as mentioned

in the repair section of this manual must be

performed after the unit has been removed

from the vehicle .

fluIds

The fluids used in Hydro-Gear products have

been carefully selected, and only equivalent, or

better products should be substituted .
Typically, an engine oil with a minimum rating

of 9 .0 cSt (55 SUS) at 230°F (110° C) and an API

classification of SL is recommended. A 20W-50

engine oil has been selected for use by the factory

and is recommended for normal operating

temperatures .

fluId VOlume and leVel

Fluid volume information is provided in the

Table below .
Certain situations may require additional fluid

to be added or even replaced . Refer to Page

10, Figure 3 and pages 4 and 5 for the proper

fill port location.
Fill the T2 to the bottom of the oil fill port

threads .
Recheck the fluid level once the unit has been

operated for approximately 1 minute .
Purging may be required . Refer to the purging

procedures on page 11 .

fluid description

Type: 20W50 motor oil

fluid Volume (per transaxle)

10 Bolt Housing: 69.3 - 65.9 fl.oz. (2050 - 1950 ml)
14 Bolt Housing: 72.8 - 69.4 fl. oz. (2155 - 2055 ml)