10
4

Blades off: Right deck fault
Restart, if problem per-
sists contact service

Fault

Disables Blades

16384

POST dynamic gating test

Controller failure

Overload: Slow down or
raise deck

Fault

Disables Blades and Drive

32768

Instantaneous under volt-
age

Momentary drop in bat-
tery voltage from the
motor pulling too much
current, short bursts

Stopped: Drive sensor
fault / Restart, if problem
persists contact service

Fault

Disables Blades and Drive

Interlock 1
code 1

Dual Throttle Input Signals
differ by more than
allowed tolerance

Poor connection, faulty
switch, damaged harness

Stopped: Drive sensor
fault / Restart, if problem
persists contact service

Fault

Disables Blades and Drive

Interlock 1
code 2

CRC check off throttle cali-
bration parameters has
failed

TPS needs to be re-cali-
brated

Stopped: Drive sensor
fault / Restart, if problem
persists contact service

Fault

Disables Blades and Drive

Interlock 1
code 4

Throttle not in neutral
when trying to close main
contactor

Drive pedal being acti-
vated, calibration error

Stopped: Drive sensor
fault / Restart, if problem
persists contact service

Fault

Disables Blades and Drive

Corrupt calibration param-
eters and VCM doesn't
know which throttle input
signal to use.

TPS needs to be re-cali-
brated

Stopped: Over-voltage /
Restart, if problem persists
contact service

Fault

Disables Blades and Drive

Controller voltages greater
than 59V for more than 5
continuous seconds.

Batteries over charged

Message

Message

type

Mower's action

Code

number

(engineering

screen)**

Trigger

Possible causes