Cub Cadet RZT-S Zero Electric User Manual
Page 103

Electrical System
99
Overload: Slow down or
raise deck
Fault
Disables Blades and Drive
32768
Instantaneous under volt-
age
Momentary drop in bat-
tery voltage from the
motor pulling too much
current, short bursts
Stopped: Right hub fault /
Restart, if problem persists
contact service
Fault
Disables Blades and Drive
1
Controller over voltage
Batteries over charged,
usually from regen. brak-
ing
Stopped: Right hub fault /
Restart, if problem persists
contact service
Fault
Disables Blades and Drive
2
Phase over current
Motor pulling too much
current, short bursts
Stopped: Right hub fault /
Restart, if problem persists
contact service
Fault
Disables Blades and Drive
4
Current sensor calibration
Internal controller issue
Stopped: Right hub fault /
Restart, if problem persists
contact service
Fault
Disables Blades and Drive
8
Not used
Stopped: Right hub fault /
Restart, if problem persists
contact service
Fault
Disables Blades and Drive
16
Controller temperature is
over 100
o
C
Controller overheating
from the motor pulling too
much current, usually from
being overloaded, faulty
controller
Stopped: Right hub fault /
Restart, if problem persists
contact service
Fault
Disables Blades and Drive
32
Motor hall sensor fault
Disconnected harness
connector, damaged har-
ness, corrosion, faulty
motor
Overload: Slow down or
raise deck
Fault
Disables Blades and Drive
64
Controller under voltage
Battery voltage too low,
poor connection, corrosion
Message
Message
type
Mower's action
Code
number
(engineering
screen)**
Trigger
Possible causes