Electrical System
10
1
Blades off: Left deck fault
Restart, if problem per-
sists contact service
Fault
Disables Blades
2
Phase over current
Motor pulling too much
current, short bursts
Blades off: Left deck fault
Restart, if problem per-
sists contact service
Fault
Disables Blades
4
Current sensor calibration
Internal controller issue
Blades off: Left deck fault
Restart, if problem per-
sists contact service
Fault
Disables Blades
8
Not used
Blades off: Left deck fault
Restart, if problem per-
sists contact service
Fault
Disables Blades
16
Controller temperature is
over 100
o
C
Controller overheating
from the motor pulling too
much current, usually from
being overloaded, faulty
controller
Blades off: Left deck fault
Restart, if problem per-
sists contact service
Fault Disables
Blades
32
Motor
hall
sensor fault
Disconnected harness
connector, damaged har-
ness, corrosion, faulty
motor
Overload: Slow down or
raise deck
Fault
Disables Blades and Drive
64
Controller under voltage
Battery voltage too low,
poor connection, corrosion
Blades off: Left deck fault
Restart, if problem per-
sists contact service
Fault
Disables Blades
128
POST static gating test
Controller failure
Blades off: Left deck fault
Restart, if problem per-
sists contact service
Fault
Disables Blades
512
Instantaneous phase over
current
Motor pulling too much
current, short bursts
Blades off: Left deck fault
Restart, if problem per-
sists contact service
Fault
Disables Blades
1024
Motor has reached at tem-
perature of 105
o
C
Motor over loaded, faulty
Message
Message
type
Mower's action
Code
number
(engineering
screen)**
Trigger
Possible causes