Cub Cadet RZT-S Zero Electric User Manual
Page 100
![background image](/manuals/656877/100/background.png)
RZT-S Zero
96
To Start: Sit in seat
Starter disable
Won't start until condition
met.
0 volts at pin B3 and B4
Seat switch is not being
depressed, poor connec-
tion, faulty switch, dam-
aged harness
To Start: Push blade knob
down/off
Starter disable
Won't start until condition
met.
5 volts at pin B5 and B6
PTO switch is ON, defec-
tive switch or a short in the
harness
To Start: Remove foot from
drive pedal
Starter disable
Won't start until condition
met.
Throttle signal not at cali-
brated neutral voltage
Drive pedal is not in a neu-
tral position or the TPS is
out of calibration
To Start: Place foot on
brake pedal
Starter disable
Won't start until condition
met.
0 volts at pin B1
Brake pedal is not
depressed, poor connec-
tion, faulty switch, dam-
aged harness
To Start: Press and hold
start/stop button
Starter disable
Won't start until condition
met.
Waiting for operator to
press and hold start but-
ton
Sometimes this condition
will appear to be met (the
graphic on the screen
changes) but the tractor
does not start (contactor
doesn't close) - This could
be a faulty VCM or com-
munication issue on the
control panel
Blades off: Overload /
Raise deck, restart blades
Operator error
Disables Blades
The speed of one or both
deck motors has fallen
below 2400 RPM for more
than 1 second
The blade speed is to low
for current cutting condi-
tions, the deck has stalled
due too much grass mate-
rial being cut at once or a
mechanical binding of the
deck motor.
Message
Message
type
Mower's action
Code
number
(engineering
screen)**
Trigger
Possible causes