Cub Cadet RZT-S Zero Electric User Manual
Page 102
RZT-S Zero
98
Stopped: Left hub fault /
Restart, if problem persists
contact service
Fault
Disables Blades and Drive
32
Motor hall sensor fault
Disconnected harness
connector, damaged har-
ness, corrosion, faulty
motor
Overload: Slow down or
raise deck
Fault
Disables Blades and Drive
64
Controller under voltage
Battery voltage too low,
poor connection, corrosion
Stopped: Left hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
128
POST static gating test
Controller failure
Stopped: Left hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
512
Instantaneous phase over
current
Motor pulling too much
current, short bursts
Stopped: Left hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
1024
Motor has reached at tem-
perature of 105
o
C
Motor over loaded, faulty
Stopped: Left hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
2048
Throttle voltage outside
range
N/A
Stopped: Left hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
4096
Instantaneous controller
over voltage
Batteries over charged,
usually from regen. brak-
ing
Stopped: Left hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
8192
Internal error
Controller failure
Stopped: Left hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
16384
POST dynamic gating test
Controller failure
Message
Message
type
Mower's action
Code
number
(engineering
screen)**
Trigger
Possible causes