Cub Cadet RZT-S Zero Electric User Manual
Page 104
![background image](/manuals/656877/104/background.png)
RZT-S Zero
10
0
Stopped: Right hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
128
POST static gating test
Controller failure
Stopped: Right hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
512
Instantaneous phase over
current
Motor pulling too much
current, short bursts
Stopped: Right hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
1024
Motor has reached at tem-
perature of 105
o
C
Motor over loaded, faulty
Stopped: Right hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
2048
Throttle voltage outside
range
N/A
Stopped: Right hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
4096
Instantaneous controller
over voltage
Batteries over charged,
usually from regen. brak-
ing
Stopped: Right hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
8192
Internal error
Controller failure
Stopped: Right hub fault /
Restart, if problem per-
sists contact service
Fault
Disables Blades and Drive
16384
POST dynamic gating test
Controller failure
Overload: Slow down or
raise deck
Fault
Disables Blades and Drive
32768
Instantaneous under volt-
age
Momentary drop in bat-
tery voltage from the
motor pulling too much
current, short bursts
Blades off: Left deck fault
Restart, if problem per-
sists contact service
Fault
Disables Blades
1
Controller over voltage
Batteries over charged,
usually from regen. brak-
ing
Message
Message
type
Mower's action
Code
number
(engineering
screen)**
Trigger
Possible causes