4 installing the device, 1 tabletop or shelf installation, Installing the device -3 3.4.1 – Cabletron Systems 2H23-50R User Manual
Page 29: Tabletop or shelf installation -3, Section 3.4

Installing the Device
2H23-50R/2H33-37R User’s Guide
3-3
3.4
INSTALLING THE DEVICE
The 2H23-50R and 2H33-37R may be installed on a tabletop, shelf, or in
a 19-inch rack.
describes a tabletop or shelf installation, and
describes the rackmount installation.
3.4.1
Tabletop or Shelf Installation
The following two subsections provide guidelines for installation on a
tabletop or shelf.
Guidelines for Tabletop and Shelf Installations
Tabletop and shelf installations must be within reach of the network
cabling and meet the requirements listed below:
•
Locate the 2H23-50R or 2H33-37R within seven feet of an
appropriately grounded power receptacle that meets the power supply
requirements listed in
•
In a shelf installation, ensure that the shelf can support 13.6 kg (30 lb)
of static weight for each device.
•
Maintain a temperature between 5°C (41°F) and 40°C (104°F) at the
installation site with fluctuations of less than 10°C (18°F) per hour.
•
Maintain a 2-inch clearance from the left, right, and rear sides of the
device to provide adequate ventilation.
Installation
For a tabletop or shelf installation, locate the device within seven feet of
its power source and with an unrestricted free surface area as shown in
for power connection instructions.
To prevent possible personal injury and/or damage to the unit,
do NOT connect power to the device until instructed to do so.
!
CAUTION
To ensure proper ventilation and prevent overheating, leave a
minimum clearance space of 5.1 cm (2.0 in) at the left, right,
and rear of the device.