Carrier Container Refrigeration Unit User Manual
Page 33

3-16
62-02575-07
Custom Controller Configuration
Allows the user to change the selectable configuration variables and save those values into a new configuration model.
The following screen is displayed when this option is chosen.
The following is a summary of the options available in Custom Controller Configuration.
Defrost Interval Save -- Allows the user to save or not save the defrost interval.
temperature sensor.
Arctic Mode -- Allows the user to enable/disable the arctic mode.
Bulb Mode -- Allows the user to enable/disable the bulb mode.
sensor. This is an Micro-Link 2i Controller variable only.
Probe Check Logic -- Allows the user to set the probe check logic to standard or special. This is an Micro-Link 2i
Controller variable only.
Suction Pressure Sensor -- Allows the user to configure or not configure the controller with a suction pressure
sensor. This is an Micro-Link 2i Controller variable only.
Micro-Link 2i Controller variable only. Save -- Allows the user to save the configuration variable values. Upon pressing the “S” key, the user is allowed to
enter up to 14 characters for the custom configuration name. Upon accepting the new name, the configuration is saved
in the custom.cnf file. The new name will be displayed in the available configurations on the controller configuration
screen.