Table 1-4 DataCORDER Events -- Continued

Event

When Event Occurs

Data Stored

Limits

Power ON (ON)

Restoration of AC power

with no battery pack pres-

ent

NA

NA

Data Retrieval

Extraction of data from

the DataCORDER

NA

NA

Real Time Clock Change

User modifies the real

time clock (RTC)

New Date and Time; Old

Date and Time

NA

RTC Battery Replaced

Real Time Clock (RTC)

battery internal to Data-

CORDER is replaced

NA

Last 1 per hour, last 1 per

day

Controller Not

Responding (NWF)

DataCORDER attempted

to communicate with

Controller, but received

no response

NA

NA

Controller Responding

(NWR)

DataCORDER was able to

establish communications

with Controller, after a

failed attempt.

NA

NA

DataCORDER

Configuration Reset

Whenever the Data-

CORDER detects an in-

valid configuration

NA

First 1 per hour, first 1 per

day

Probe Calibration

When Calibration offset

values are entered

NA

Last 6 per hour, last 24

per day

Table 1-5 Controlled Atmosphere (CA) Events Recorded in the DataCORDER

Event

When Event Occurs

Data

Limits

CA Communications

Failure

When communication

with the CA controller is

lost

NA

First 1 per hour, first

24 per day

CA Communications

Recovery

When communication

with the CA controller is

regained

NA

Last 1 per hour, first

24 per day

CA Set Point Change

(CA-SP)

Whenever the O

2

or CO

2

set point is changed

O

2

set point, CO

2

set point

Last 1 per hour, last 6

per day

CA Alarm Reset

Whenever the CA alarm

list is reset

Last 2 per hour, last

10 per day

CA Alarm Activity

Case 1: Whenever an

alarm changes state

Case 1: Alarms active during this

hour

Case 1: 1 per hour

which is a combina-

tion of all events in

that hour

CA Alarm Activity

(CA-AL)

Case 2: At the end of any

hour where an alarm ac-

tive during that hour is

inactive at the end of the

hour.

Case 2: Currently active alarms

Case 2: 1 per hour

CA Pre-Trip Start

(CA-PS)

Whenever CA Pre-Trip is

initiated, or is active at

midnight

Source (keypad, communica-

tions, or active at midnight)

First 1 per hour, first

4 per day

CA Pre-Trip End

(CA-PE)

Whenever CA Pre-Trip is

completed

Test data for all CA Pre-Trip tests

run since the last power on.

Last 1 per hour, first 4

per day