beautypg.com

Carrier Container Refrigeration Unit User Manual

Page 19

background image

3-2

62-02575-07

Printers Supported

1. EPSON 85 dot matrix or compatible (most dot matrix printers support this format).
2. HP Laser Jet or equivalent (many laser printers support this format).
For printers that are not compatible with the above printers, select the FILE printer port option in printer setup. This

will send the report to an ASCII print file.

TOPIC 2 DESKTOP QUICK START

This section describes the installation procedure for the DOS DataView interrogator program.

Installation From MS--DOS Prompt

This installation procedure will copy the DataView Program to a hard --disk. Approx. 1.5MB of files will be copied.

NOTE

The data view package contains two diskettes. disc part number 12--00413--05 loads software for use with
reciprocating compressor units. Disc 12--00528--00 loads software for use with scroll compressor units. Both
software programs may be loaded on the same computer except different resident directories must be created.

Each DOS DataView program comes on a single 3.5--inch diskette. To begin installation insert the diskette into drive

A:\ or drive B:\. Depending on the drive the diskette is loaded in, at the MS--DOS system prompt type A:\install or

B:\install and press the enter key. The installation program will take the user through the following steps:
a) The startup screen is displayed. Press enter to continue.
b) The product selection screen is displayed. Select which DOS DataView product to install DataView onto: a PC,

Hewlett Packard (HP) Palmtop or pen based computer. Use the up/down arrow keys to highlight the product, and the

space bar select the product, and press enter to continue.

NOTE

If loading scroll software on the same computer as reciprocating software the destination directory must be
changed. Suggested change is C:\SCROLLDV. If the destination directory is not changed, installation of new
reciprocating software will overwrite the scroll software.

c) The destination directory selection screen is displayed. Enter the directory the DataView program will reside in and

press enter. The default directory is “C:\DATAVIEW.” If this directory does not exist on the PC, the installation

program will automatically create the directory.

d) To preserve the previous sensor configuration file, sensors.cnf, the file is copied to sensors.sav.
e) To preserve the previous program configuration file, ml2.cnf, the file is copied to ml2.sav.
f) The custom.cnf, *.DCX, and *.PRN files will not be delete and will remain in the directory.
g) The previous version of the DataView program will be deleted prior to installing the new program.
h) All of the files are downloaded to the directory defined in step c. As the files are downloaded to the computer, a

progress bar is displayed to indicate the amount of files successfully downloaded. The following files will reside in

the directory defined in step c.

DATAVIEW.EXE

Main Program

RPTVIEW.EXE

Report Generator Program

PRNTFILE.EXE

Print Report Program

COREMON.EXE

Micro-Link 2/2i Monitor Program

CTD2.EXE

Micro-Link 1 Program

SELFILE.EXE

DataReader Program -- not included with the HP Palmtop or

Pen--Based computer.

HELP.DAT

Help data file

CONTHELP.DAT

Controller Monitor Help data file

CGA.BGI

Graphics driver

EGAVGA.BGI

Graphics driver

ML2.CNF

Program configuration file

MODELS2.CNF

Model controller configuration file

SENSORS.CNF

Sensor configuration file