1.3 DataCORDER INTERFACE

The DataCORDER is capable of performing the following functions initiated by the DataView Program

1.3.1 Data Extraction
a. Daily Header Data

Recorded days are presented in the following format:
1. Day 1 date (month, day, year), sensor data, events, ...
2. Day 2 date (month, day, year), sensor data, events, ...

b. Sensor Data

Sensor data will be read based on either standard or generic configuration. Please refer to separately bound manuals

covering the Refrigeration Unit for further explanation of standard and generic configurations, see Table 1-2.

1.3.2 Events

Events will be transmitted to the DataCORDER as specified in Table 1-3, Table 1-4 and Table 1-5. The

DataCORDER compacts the events, disposing of repetitive events to save memory space. All events have a time and

date stamp.

Table 1-3. Temperature Controller Events

Event

When Event Occurs

Data Stored

Limits

Set Point Change (SP)

Whenever the temperature

set point changes

New set point; method

used to change it

Last 1 per hour, last 6 per

day.

Defrost Start (DS)

Whenever a defrost cycle

is initiated and when the

system is in defrost mode

at midnight

Source of initiation (key-

pad, communications, tim-

er, or active from previous

day)

First 1 per hour, first 10

per day.

Defrost End (DE)

Whenever a defrost cycle

is terminated

Source of termination

(normal, timer, or HTT)

Last 1 per hour, last 10 per

day

Pre-Trip Start (PS)

Whenever Pre-Trip starts

or is active at midnight

Source of initiation (key-

pad, communications, or

active from previous day)

First 1 per hour, first 4 per

day.

Pre-Trip End (PE)

Whenever Pre-Trip com-

pletes.

Pass/Fail data for each test

run since last power up

Last 1 per hour, last 4 per

day.

Dehumidification Start

(DHS)

Whenever dehumidifica-

tion is initiated, or is ac-

tive at midnight

Set point, humidity read-

ing type (active at mid-

night or normal)

First 1 per hour, first 10

per day.

Dehumidification End

(DHE)

Whenever dehumidifica-

tion ends

Set point, humidity read-

ing

Last 1 per hour, last 10 per

day

Humidification Start

(HS)

Whenever humidification

is initiated, or is active at

midnight or “htESt” is run

Set point, humidity read-

ing, method used to cause

it

First 1 per hour, first 10

per day.

Humidification End

(HE)

Whenever humidification

ends

Set point, humidity read-

ing

Last 1 per hour, last 10 per

day

Humidity Set Point

Change

Whenever humidity set

point changes

New set point, method

used to change it

N/A

Controller Alarm

Case 1: Whenever an

alarm changes state

Case 1: Alarms active dur-

ing this hour

Case 1: 1 per hour which

is a combination of all

alarm events in that hour

Controller Alarm

Activity (AL)

Case 2: At the end of any

hour where an alarm active

during that hour is inactive

at the end of the hour

Case 2: Currently active

alarms

Case 2: 1 per hour

Controller S/W Upgrade Any change in the Con-

troller software revision.

New software version

Last 1 per day.

Container ID Change

Any time the container ID

is changed

New ID

Last 1 per day