1-9

62-02575-07

Table 1-5 Controlled Atmosphere (CA) Events Recorded in the DataCORDER -- Continued

Event

When Event Occurs

Data

Limits

O

2

Air Calibration

Whenever O

2

Air Cal-

ibration is completed

New calibration value; Result

(pass, fail, or low) Source (key-

pad, communications, or timer)

Last 2 per hour, last

10 per day

O

2

Gas Calibration

Whenever O

2

Gas Cal-

ibration is completed

New calibration value; Result

(pass or fail) Source (keypad,

communications, or timer)

Last 2 per hour, last

10 per day

CO

2

Zero Calibration

Whenever CO

2

Zero Cal-

ibration is completed

New calibration value; Result

(pass or fail, no gas) Source (key-

pad, communications, or timer)

Last 2 per hour, last

10 per day

Lockout Start

Whenever the Tempera-

ture Controller initiates a

lockout of CA operation

Type: normal, or active at mid-

night

First 1 per hour

Lockout End

Whenever the Tempera-

ture Controller enables

CA operation.

NA

Last 1 per hour.

CA Configuration

Change

Any time the CA unit

configuration changes

Configuration variables

Last 2 per hour, last

10 per day

CA Nitrogen Test

Any time a nitrogen test

is completed

N

2

purity values for last low, me-

dium, and high flow tests, and

flags to indicate whether low,

medium and high values are in

range

Last 2 per hour, last

10 per day

CA Service Activity

Any time ‘‘service the fil-

ter’’ hours or compressor

hours expires or is reset,

or the O

2

sensor’s life is

detected to be low, or the

O

2

sensor is detected re-

placed

Filter hours expired; filter hours

reset; compressor hours expired;

compressor hours reset; O

2

sen-

sor life low; O

2

sensor expired;

filter, compressor, and total run

hours

First 1 per hour

CA Software Upgrade

Any time the CA soft-

ware revision changes

New software version

Last 1 per day

CA Controller Replaced

Any time the CA Con-

troller serial number

changes

New serial number

Last 1 per day

Door Lock (CA-DL)

Any time the CA door is

locked by the Controller

NA

Last 1 per hour

Door Unlock (CA-UL)

Any time the CA door is

unlocked by the Control-

ler

NA

Last 1 per hour

Vent Mode Start

(CA-VS)

Any time CA vent mode

is initiated

NA

Last 1 per hour

Vent Mode End

(CA-VE)

Any time CA vent mode

is terminated

NA

Last 1 per hour