Port Name

Connection Function

1~16

Alarm input port.
1~16

I/O port

 Four groups of alarm input ports. The first

group is from port 1 to port 4, the second

group is from port 5 to port 8, the third

group is from 9 to 12, and the fourth group

is from 13 to 16. They are to receive the

signal from the external alarm source.

There are two types; NO (normal open)/NC

(normal close).

 When your alarm input device is using

external power, please make sure the

device and the NVR have the same

ground.

Ground end

Alarm input ground end.

NO1~NO5

Alarm output
port 1~5

5 groups of alarm output ports. (Group 1:port

NO1~C1,Group 2:port NO2~C2,Group
3:port NO3~C3.group 4: port NO4~C4、
Group 5:port NO5、C5、NC5).Output alarm
signal to the alarm device. Please make sure
there is power to the external alarm device.

NO:Normal open alarm output port.

C:Alarm output public end.

NC: Normal close alarm output port.

C1~C5

NC5

A

RS485 port

RS485_A port. It is the cable A. You can
connect to the control devices such as speed
dome PTZ.

B

RS485_B.It is the cable B. You can connect to
the control devices such as speed dome PTZ.

CTRL 12V

Controllable 12V power output. It is to control
the on-off relay output. You can use it to enable
device alarm function.

It can also be used as the power input for some
alarm devices such as the smoke detector.

+12V

+12V power output port. It is to provide the
power to the peripheral devices such as camera
or alarm device. The connected device current
shall be less than 1A.