Overall system overview, English, General – Pilz PSEN enc s2 eCAM User Manual
Page 8
General
6
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland
Telefon +49 711 3409-0, Telefax +49 711 3409-133, E-Mail: [email protected]
English
1.3.2 Overall system overview
Antrieb
Welle
SSI
SSI
Inkremental-
Interface
optische Abtastung
magnetische Abtastung
N
S
Anschlussklemme
Fig. 1: System schematic
A
Measuring channel 1, single-turn and multi-turn
● Optical detection of the number of steps/revolution
● Max. 8192 steps/revolution, accuracy: 13 Bit
● Synchronous serial interface (SSI)
● Incremental signals for position feedback
B
Measuring channel 1, multi-turn
● Magnetic detection of the number of revolutions
● Max. 4096 revolutions
● Synchronous serial interface (SSI)
C
Measuring channel 2, single-turn and multi-turn
● Magnetic detection of the number of steps/revolution
● Max. 8192 steps/revolution, accuracy: 8 Bit
● Synchronous serial interface (SSI)
D
Measuring channel 2, multi-turn
● Magnetic detection of the number of revolutions
● Max. 4096 revolutions