5.7 Count direction

Fig. 11: Setting the count direction


M1: Setting for measuring channel 1
M2: Setting for measuring channel 1


Permitted switch settings measuring channel 1/ measuring channel 2:

DIP 1

DIP-Schalter 2

Count direction

OFF ON

Increasing in clockwise direction, viewed towards the flange
connection

ON OFF

Decreasing in clockwise direction, viewed towards the flange
connection


NOTICE

The count direction for measuring channel 1 and
measuring channel 2 must be set in opposite
direction!