Installation / Preparation for commissioning

30

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland

Telefon +49 711 3409-0, Telefax +49 711 3409-133, E-Mail: [email protected]

English

5.6 Shield connection

The shield connection is made via special EMC-compliant cable screw connections, in
which the cable shield can be connected internally.

Cable screw connection assembly, type A




Pos. 1 Union nut

Pos. 2 Sealing insert

Pos. 3 Contact sleeve

Pos. 5 Screw socket



1. Trim the shield braid / shield foil to the dimension "X".
2. Slide the union nut (1) and sealing insert / contact sleeve (2) + (3) over the

cable.

3. Bend the shield braid / shield foil by approx. 90° (4).
4. Slide the sealing insert / contact sleeve (2) + (3) up to the shield braid / shield

foil.

5. Fit the screw socket (5) on the housing.
6. Push the sealing insert / contact sleeve (2) + (3) flush into the screw socket

(5).

7. Screw the union nut (1) to the screw socket (5).