Installation / Preparation for commissioning

Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Deutschland

Telefon +49 711 3409-0, Telefax +49 711 3409-133, E-Mail: [email protected]

39

English

5.10 LED status display

Fig. 15: LED status display



Power LED, green

CH1: Measuring channel 1, CH2: Safety system

OFF

Supply voltage absent or outside the range 11…28 VDC,
hardware error

ON

Ready for operation, normal condition



Error LED, red

CH1: Measuring channel 1, CH2: Safety system

OFF

Ready for operation, no fault

ON

Fault condition; general fault indicator for faults which
result in the data output being shut down.

Exception:
If there is a fault in the incremental channel, the LED is
also ON, but the SSI remains operational.