14. Resetting the GLD


There are different ways you can reset GLD settings:

Use the surface Reset key to reset parameters

Recall a Library to overwrite processing

Recall a Scene to overwrite multiple parameters

Recall A Show to overwrite all settings and Scenes

Perform a Full System Reset using power up page

Reset User Profiles and passwords using an internal

jumper.

Save settings before resetting the system

Performing a reset overwrites GLD settings. If you wish to

keep current settings then make sure you save them first.

‘Reset’ Scene
Factory default Template Shows include a ‘Reset’ Scene in

position 1 (GLD-80) and 2 (GLD-112) to instantly reset

parameters to the Template default without affecting the mix

configuration, user preferences and other Scenes. These

are backed up in Scenes 499 and 500. You can recall this

Scene or any other you have set up as your own starting

point. Protect parameters from Scene recall using its Scene

Recall Filter and global Scene Safes.

Starting with a Template or User Show

If you want clear the GLD for a new event or after another

user has finished you can load one of the several factory

default Template Shows or a User Show. This will clear all

Scenes and reset all settings to a familiar configuration and

layout. To load a Show go to the

Setup / Memories / Show

Manager

screen.


Loading a Template Show will:

Restore a default configuration and layout

Reset user preferences

Zero the board current settings

Reset the processing, routing and patching

Clear all Scenes

Clear all User Libraries

Note

Loading a Template or User Show overwrites all

Scenes and Libraries. Back these up first if you want to

keep them.


_____________________________________________________

To clear User Profiles and Passwords
This requires a hard reset by setting a jumper within the

GLD. Disassembly is required.
Contact the Allen & Heath service agent or distributor in

your territory for further information.

System Reset
This should only be done if you need to completely wipe

the memory and restore the GLD to its factory default reset

settings.

A Full System Reset will:

Restore a reset configuration, layout and preferences

Reset the processing, routing and patching

Clear all Scene memories

Clear all Libraries

Clear all Shows stored in the GLD

A Full Reset does not clear User Profiles and passwords.

Note

Before you start, make sure you have copied any

User Shows you wish to keep to your USB key.

To fully reset the GLD first power it off without using the

Home

screen

Power Down

button. Power up and wait for

the ‘GLD not shut down correctly’ screen to appear.

Touch the Advanced button and then touch Reset GLD.

Confirm that you wish to do this. Touch OK to reboot the

system into its reset state.


Once the reset is complete we recommend you load a

Template or User Show.