0 operation, 1 semi-automatic tare (net/gross), 2 preset tare (subtractive tare device) – Rice Lake SCT-10 User Manual
Page 36: Operation

32 SCT Weight Transmitter Operator’s Manual
3.0 Operation
3.1
Semi-Automatic Tare (Net/Gross)
The semi-automatic tare value is lost upon instrument power-off.
The semi-automatic tare operation is not allowed if the gross
weight is zero.
1. To capture tare and weigh in net mode (SEMI-AUTOMATIC TARE),
close the NET/GROSS input or press
for 3 seconds. The
instrument displays the net weight (zero) and the NET LED lights up.
2. To display the gross weight again, keep the NET/GROSS input closed
or press
for 3 seconds.
3. This operation can be repeated by the operator to allow the loading of
several products.
Press and hold
to display the gross weight temporarily. When
is released, the net weight will be displayed again.
3.2
Preset Tare (Subtractive Tare Device)
It is possible to manually set a preset tare value to be subtracted from the display
value provided that the P-tArE ≤ max capacity.
1. Press and hold
and
to display P-tArE, press
.
2. Press
or
until desired value is displayed, press
.
3. Press
to exit P-tArE.
4. After setting the tare value, go back to the weight display, the display
shows the net weight (subtracting the preset tare value) and the NET
LED lights up to show that a tare has been entered.
Press and hold
for 3 seconds to display the gross weight
temporarily. When
is released, the net weight will be
displayed again.
To delete a preset tare and return to the gross weight display:
1. Press hold
for 3 seconds or keep the NET/GROSS input (if any)
closed for the same length of time (3 seconds). The preset tare value is
set to zero. The NET LED is turned off when the gross weight is
displayed once again.
Note
TARE
TARE
Note
MENU
TARE
MENU
TARE
MENU
0
ESC
Note
TARE