Controls
Calibrate – Sensor calibration interface. Details provided in the Section 4.1 on page 12.
Edit Standard Mode – This control allows editing of the standard mode, including motion detection, AZM and
Zero at power up.
Edit Zero Configuration – Edit the sensor Zero parameters. This includes adjusting the zero range, AZM
parameters and power up at zero range. These values are stored separately for each of the standard modes (i.e.
Industry, NTEP, OIML).
Edit Motion Configuration – Edit the sensor motion detection parameters. This includes the motion period, band,
and pending time.
Edit Display Configuration – Edit the sensor display parameters. This includes adjusting the capacity, countby,
units, and percent under load range. Note that the capacity and count by can be adjusted without having to
recalibrate a sensor. The capacity can be adjusted less than the calibration capacity. The countby can be adjusted
greater than the calibration countby.
Edit Tare/Total Configuration – Edit the sensor Tare and Total parameters. This includes Tare Auto Clear, Total
mode, total thresholds, total stable time, and total on accept thresholds.
Edit Peak Configuration – Edit the sample speed used when recording peak lift values.
Edit Lift Counter – Edit the sensor lift counter thresholds. These parameters relate to the service counters.
6.4 Calibration Tables
The advanced Calibration Tables view provides a list of all sensor calibration tables and their associated
configuration.
Figure 6-4. Configuration View - Calibration Tables
Standard Mode
Motion Enabled
Enable or Disable motion detection
AZM Enabled
Enable or Disable AZM (Auto Zero Maintenance)
Zero at Power Up
Enable
Standard Mode
Set the weighing mode (Industry, NTEP, OIML, 1-Unit).
Parameter
Description
Table 6-3. Load Cell and Math Sensor Parameters
- MSI-7300 Dyna-Link 2 - ScaleCore Configuration Management Program (ScCMP) MSI-4260 Port-A-Weigh - ScaleCore Configuration Management Program (ScCMP) MSI-3460 Challenger 3 - ScaleCore Configuration Management Program (ScCMP) MSI Tension Dynamometers - ScaleCore Configuration Management Program (ScCMP) MSI Indicators/Remote Displays - ScaleCore Configuration Management Program (ScCMP) MSI Crane Scales - ScaleCore Configuration Management Program (ScCMP) Crane Scales - ScaleCore Configuration Management Program (ScCMP)