JRexplus LX User's Guide

A.5 PCI

Devices

All devices follow the Peripheral Component Interconnect 2.2 (PCI 2.2) specification. Please see the speci-
fication for more details.

PCI Device

PCI IRQ

Comment

Host Bridge

None

Chipset

Graphics Controller

INTA

Chipset

ISA Bridge

None

Chipset

P-ATA Controller

None

Chipset

USB Controller 1

INTD

Chipset

USB Controller 2

INTD

Chipset

Audio Controller

INTB

Chipset

Encryption Controller

INTA

Chipset

LAN Controller

INTA

PCI bus (AD28)

S-ATA Controller

INTB

PCI bus (AD29)

A.6

System Management Bus (SMBus

TM

)

The JRexplus LX uses an onboard System Management Bus (SMBus

TM

). This bus is not available on a peri-

pheral connector and therefore cannot be used for external SMBus

TM

devices.

SMBus Address

Device

Comment

30h / 31h

GPIO Controller

Winbond I/O controller W83601

A0h / A1h

SPD Eeprom (DDR-SDRAM)

Part of the DDR RAM module


Warning: There are more devices connected to the SMBus

TM

than listed in this table but access to these devices in not permitted.

Don’t access any other device addresses except those listed above.