13 parallel-ata interface (p-ata), 1 connector, Jrex plus lx user's guide – Kontron JRexplus-LX User Manual
Page 29
KTD-S0001-C
Page 25
Parallel-ATA Interface (P-ATA)
JRexplus LX User's Guide
13 Parallel-ATA Interface (P-ATA)
The JRexplus LX features one Parallel-ATA interface (Primary channel, UDMA33/66 mode) that can drive
two hard disks. When two devices share a single adapter they are connected in a master/slave, daisy-chain
configuration. If only one drive is connected you must set it as master. Alternatively the same interface can
be used for Compact Flash card applications. Due to mechanical restrictions KONTRON chipdisks can't be di-
rectly mounted. A stand-off extension for the pingrid is needed to connect the chipdisk properly.
13.1 Connector
The P-ATA interface is available through connector X6 (44 pins). This interface is designed in 2 mm grid for
optimal connectivity to a 2.5” hard disk. You can use two cables to directly connect a hard disk in a 2.5”
form factor (KAB-IDE-2MM, part number 96021-0000-00-0) or a 3.5” form factor (KAB-IDE-25, part num-
ber 96020-0000-00-0).
Header
Pin Signal Name
Function
Pin Signal Name
Function
1
/RESET
Reset
2
GND
Ground
3
D7
Data 7
4
D8
Data 8
5
D6
Data 6
6
D9
Data 9
7
D5
Data 5
8
D10
Data 10
9
D4
Data 4
10
D11
Data 11
11
D3
Data 3
12
D12
Data 12
13
D2
Data 2
14
D13
Data 13
15
D1
Data 1
16
D14
Data 14
17
D0
Data 0
18
D15
Data 15
19
GND
Ground
20
KEY (N.C.)
Key pin
21
DRQ
DMA request
22
GND
Ground
23
/IOW
I/O write
24
GND
Ground
25
/IOR
I/O read
26
GND
Ground
27
IOCHRDY
I/O channel ready
28
CSEL
2)
Cable select
29
/DACK
DMA acknowledge
30
GND
Ground
31
IRQ
Interrupt request
32
N.C.
Not connected
33
SA1
Address 1
34
ATAD
UDMA detection
35
SA0
Address 0
36
SA2
Address 2
37
/CS1
Chip select 1
38
/CS3
Chip select 3
39
ACT
Drive activity
40
GND
Ground
41
VCC
1)
Power +5V
42
VCC
1)
Power +5V
43
GND
Ground
44
N.C.
Not connected
Note:
1)
To protect the external power lines of peripheral devices make sure that
- the wires have the right diameter to withstand the maximum available current.
- to enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.
2)
Pin 28 is connected with 470
Ω
to Ground for Cable Select P-ATA devices.