EFCO 8800 Series Assembly Instructions Vol.5 User Manual
Page 51

EFCO 2009
Page 51
Series 8700 / 8800 Unitized Curtain Wall Assembly Instructions - Volume 5
Section 25 - Captured Vent Unit Glazing at Stack Sill : C. Adapter Installation
Figure 87
HEAD
SILL
19. Slide WS00 vent surround gaskets into the 17L4 pocket fillers with the gaskets positioned with the rounded face of the gasket toward the exterior. WS00
runs the full length of the pocket filler.
20. Insert the pocket fillers into both glazing pockets of the jambs at the vent opening. Slide the pocket fillers to the exterior as shown in Figures 88 and 89.
21. Drive in the WVD1 wedge retainer gasket between the pocket filler and mullion. WVD1 runs the full length of the pocket filler. No sealant is required for
Slide WS00 gasket into
the 17L4 pocket filler and
insert the pocket filler
into the glazing pocket.
Drive in WVD1 gasket to
retain the pocket filler.
WC22 Wedge
Gasket
WS00 Vent
Surround Gasket
17L4 Pocket
Filler
WC22 Wedge
Gasket
WS00 Vent
Surround Gasket
Slide WS00 gasket into
the 17L4 pocket filler and
insert the pocket filler
into the glazing pocket.
Drive in WVD1 gasket to
retain the pocket filler.
WC22 Wedge
Gasket
WS00 Vent
Surround Gasket
Figure 88
Figure 89