Secured series front end mode default settings – Detex DTX-2300 User Manual
Page 28

Prox.pad Installer Guide
Document # 6-055678 X2
Page 28 of 32
Secured Series Front End Mode LED Indicators/Sounder
LED/Sounder
Visual/Audible Condition
Description
Yellow LED
Slow blink
Unit is in program mode
Rapid blink
Verify mode is active (checking that the last two values in sequence
match)
Steady
Program error; entry error lockout (no keypress feedback)
Very rapid blink
Memory (eeprom) erase is in progress (command 46)
“Pulsing” rapid blink
Batch program of cards in progress (command 56); block delete of
users (command 58)
Bi-color LED
Steady red
Lock is locked
Steady green
Lock is energized (timed or latched)
Quick double red/green fl ash
Prox card read correctly
All LED's
Rapid red, yellow, green
sequencing
Power on/reset
Sounder
(system)
Very quick beep (10 ms) with
yellow LED blink every second
EEPROM read error during get system parameters; can be turned
off by running self-test
3 slow beeps (250 ms)
Indicates self test
Sounder (after
PIN)
3 rapid beeps after
PIN not found
Sounder (after
card)
3 very rapid beeps
PIN not found, facility code/company ID mismatch and access by
facility mode enabled; incorrect card type (option #20)
1 short beep
Valid card access
Secured Series Front End Mode Default Settings
Option
Default Setting
Option
Default Setting
Master Code
1234
Audio Keypress Feedback
Enabled
Visual Keypress Feedback
Enabled
Auto-Entry
Disabled
Anti-Passback
Enabled
Reader In/Out Select
In
Keypad In/Out Select
In
Prox Card Type
26-bit
Facility Match Required
Disabled
Facility Code
1
Corporate 1000 ID
4095