Standalone mode program commands – Detex DTX-2300 User Manual
Page 20

Prox.pad Installer Guide
Document # 6-055678 X2
Page 20 of 32
Standalone Mode Program Commands
If you need to change any of the program default values or wish to add functions, fi rst enter program mode and then enter
the desired program command. Defaults are in bold.
Note: The master code must be changed prior to performing any programming on the prox.pad unit. When programming
users, the term user location refers to the place in the units memory that the user is stored.
Action Desired
Press
Details
Enter Program Mode
99 # (Master Code)
✱
Yellow LED blinks slowly
Change master code
1 # (new code)
✱ (repeat code) ✱
Ex: 1 # 4321
✱ 4321 ✱
Enter new code
Set main relay time
11 # tt # 0 #
✱ ✱
tt=1-99 seconds (default =
5 seconds)
Set AUX relay output
15 # output # 0 #
✱ ✱
0=disabled
1=shunt (default)
2=forced door
3=propped door
Delete Users
user location #
✱ ✱
Set/clear standard option
30 # option # s/c #
✱ ✱
See Chart below
Option Set
Clear
0 — Audio Keypress Feedback
1 = Enabled
0 = Disabled
1 — Visual Keypress Feedback
1 = Enabled
0 = Disabled
2 — Auto Entry
0 = Disabled
1 = Enabled
3 — Operating Mode
0 = Standalone
1 = Front End
4 — Facility Code Access
0 = Disabled
1 = Enabled
5 — Forced Door Audio Alert
0 = Disabled
1 = Enabled
6 — Propped Door Audio Alert
0 = Disabled
1 = Enabled
7 — Internal REX Switch
0 = Disabled
1 = Enabled
8 — Daylight Savings Time Format
0 = US
1 = European
13 — Daylight Savings Time
0 = Disabled
1 = Enabled
14 — Prox Card Anti-Passback Select
0 = Disabled
1 = Enabled
18 — Invalid PIN Lockout Select
0 = Disabled
1 = Enabled
19 — Invalid PIN Lockout Action
0 = Timed Lockout
1 = Forced Door Output
Print User List
25 # 0 # 0 #
✱ ✱
Print User List
(From Certain User Location)
25 # 0 # start user #
✱ ✱