Detex DTX-2300 User Manual
Page 21

Prox.pad Installer Guide
Document # 6-055678 X2
Page 21 of 32
Action Desired
Press
Details
Change Platform Parameters
32 # parameter # value #
✱ ✱
See Chart Below
Parameter Value
2 — 26 Bit Facility Code
0 — 255; (Default = 1)
Note: IEI Cards are Facility Code 11
3 — Process Card Time
2 — 240; 1/4 sec. Increments
(Defaults to 4 = 1 sec.)
4 — Invalid PIN Lockout Attempts
1 — 50 (Default = 5)
5 — Invalid PIN Lockout Duration
1 — 255; 5 sec. increments;)
(Defaults to 60 = 5 Minutes)
Set System Time
41 # hhmm # 0 #
✱ ✱
hhmm=hour/minute (24 Hour Format)
Set System Date
42 # mmddyy # dow #
✱ ✱
mmddyy=month, date, year; dow=day
of week, 1=Sunday
Set Propped Door Time
44 # ttt # 0 #
✱ ✱
ttt=propped door time, to nearest
10’s seconds, entered as 30-990;
(default=30 secs)
(this sets the time for both Aux Relay
and local sounder)
Set Forced Door Time
45 # ttt # 0 #
✱ ✱
ttt=propped door time, to nearest
10’s seconds, entered as 30-990;
(default=10 secs)
(this sets the time for both Aux Relay
and local sounder)
Reset System Defaults Only
40 # 00000 # 00000 #
✱ ✱
Does not delete users
Delete Entire Memory and Reset
System Defaults
46 # 00000 # 00000 #
✱ ✱
Deletes all memory including users
Program User — Code Only
50 # user type # user location #
code
✱ repeat code ✱
User Types:
0-Toggle/latch lock
1-Normal access
2-Log Dump
3-Lockout
Program User — Code AND Card By
Presenting Card
50 # user type # user location #
code
✱ repeat code ✱ ✱
card>
User Types:
0-Toggle/latch lock
1-Normal access
2-Log Dump
3-Lockout