background image

132 Appendix D: MIDI Implementation

Dave Smith Instruments

Mod Destination

Value

Seq Out 2 Ch 14

136

Seq Out 2 Ch 15

137

Seq Out 2 Ch 16

138

Sysex Messages

Universal System Exclusive Message (Device Inquiry)

Status

Description

1111 0000 System Exclusive (SysEx)
0111 1110 Non-realtime message
0vvv vvvv

If MIDI channel is set to 1 - 16, 0vvvvvvv must match (unless MIDI

Channel = ALL); always responds if 0vvvvvvv = 0111 1111.

0000 0110 Inquiry Message
0000 0001 Inquiry Request
1111 0111

End of Exclusive (EOX)

The Pro 2 responds with:

Status

Description

1111 0000 System Exclusive (SysEx)
0111 1110 Non-realtime message
0vvv vvvv

If MIDI Channel = ALL, 0vvvvvvv = 0111 1111. Otherwise 0vvvvvvv =

Channel Number 0 - 15.

0000 0110 Inquiry Message
0000 0010 Inquiry Reply
0000 0001 DSI ID
0010 1100 Pro 2 ID (Family LS)
0000 0001 Family MS
0000 0000 Family Member LS
0000 0000 Family Member MS
0jjj nnnn

Main Software version: jjj - Minor rev; nnnn - Major rev

1111 0111

End of Exclusive (EOX)