10 Global Settings

Dave Smith Instruments

Global Settings

Press the

global

button to set parameters such as Master Tune and MIDI

Channel that affect all programs globally.

1 . Master Coarse Tune: -12…+12—

Master Transpose control, 0 is

centered. Steps in semitones up to one octave up (+12) or down (-12).

2 . Master Fine Tune: -50…+50—

Master Fine Tune control; 0 centered.

Steps in cents as much as a quarter-tone up (+50) or down (-50).

3 . MIDI Channel: All, 1…16—

Selects which MIDI channel to send and

receive data, 1 to 16. All receives on all 16 channels.

4 . MIDI Clock Mode:

Sets the Pro 2’s ability to send and receive MIDI

clock messages:

• Off: MIDI Clock is neither sent nor received
• Master: MIDI Clock is sent, but not received.
• Slave: MIDI Clock is received, but not sent.
• Slave Thru: MIDI Clock is received and passed to MIDI Out

In Slave and Slave Thru modes, if no MIDI clock is present at the selected

input, the arpeggiator and sequencer will not function.

5 . MIDI Clock Cable: MIDI Port, USB—

Sets the port, MIDI or USB, by

which MIDI clocks are received.

6 . MIDI Param Send: Off, CC, NRPN—

Changes to the values of front

panel controls are transmitted via MIDI as Non-registered Parameter

Number (NRPN) controllers or as Continuous Controllers (CC). Trans-

mission of parameters can also be turned off. See MIDI Implementation

on page 85

for details.

NRPNs are the preferred method of parameter transmission, since they cover

the complete range of all parameters, while CCs are limited to a range of 128.

7 . MIDI Param Receive: Off, CC, NRPN—

Sets the method by which

parameter changes are received via MIDI. As with transmission, NRPNs

are the preferred method.