Dell PowerEdge 1800 User Manual
Page 28
28
Indicators, Codes, and Messages
www
.dell.com | support.dell.com
Timer chip counter 2
failed
Faulty system board.
Unsupported CPU
combination
Microprocessor(s) is not supported by
the system.
Install a supported microprocessor
combination. See "Processors" in
"Installing System Options."
Unsupported CPU stepping
detected
Unsupported DIMM detected
in the RAID DIMM slot!
RAID memory module is not
supported by the system.
This message is not applicable to this
system.
Unsupported RAID key
detected!
RAID hardware key is not supported
by the system.
This message is not applicable to this
system.
Utility partition not
available
The
POST, but no utility partition exists
on the boot hard drive.
Create a utility partition on the boot
hard drive. See "Using the Dell
OpenManage Server Assistant CD" in
your
User's Guide."
The VRM for the processor
in socket
n is not
installed.
Specified microprocessor VRM is
faulty, unsupported, improperly
installed, or missing.
This message is not applicable to this
system.
Warning: Detected mode
change from RAID to SCSI
x
of the embedded RAID
subsystem.
Type of controller has changed from
optional RAID (when available) to
SCSI since previous system boot.
This message is not applicable to this
system.
Warning: Detected mode
change from SCSI to RAID
x
of the embedded RAID
subsystem.
Type of controller has changed from
SCSI to optional RAID (when
available) since previous system boot.
This message is not applicable to this
system.
Warning: Detected missing
RAID hardware for the
embedded RAID subsystem.
Data loss will occur!
Press Y to switch mode to
SCSI, press any other key
to disable both channels.
Press Y to confirm the
change; press any other
key to cancel.
Type of controller has changed since
previous system boot.
This message is not applicable to this
system.
Warning: Firmware is out-
of-date, please update.
Firmware error.
Update the firmware. See "Getting
Help."
Table 2-8.
System Messages (continued)
Message
Causes
Corrective Actions