Dell PowerEdge 1800 User Manual
Page 21

Indicators, Codes, and Messages
21
Alert! Current
configuration does not
support redundant memory.
Redundant memory is
disabled.
Memory modules installed are not the
same type and size in all banks; faulty
memory module(s).
This message is not applicable to this
system.
Amount of available memory
limited to 256 MB!
OS Install Mode is enabled in the
System Setup program.
Disable OS Install Mode in the System
Setup program. See "Using the System
Setup program" in the
User's Guide.
Auxiliary device failure
Loose or improperly connected mouse
or keyboard cable; faulty mouse or
keyboard.
See "Troubleshooting the Mouse" and
"Troubleshooting the Keyboard" in
"Troubleshooting Your System."
BIOS Update Attempt
Failed!
Remote BIOS update attempt failed. Retry the BIOS update. If problem
CD-ROM drive not found
IDE CD-ROM Controller option is
enabled in the System Setup program,
but the CD drive is not detected.
If the system does not have a CD drive,
disable the IDE CD-ROM Controller
option in the System Setup program.
See "Using the System Setup program"
in the
User's Guide.
If the system has a CD drive, ensure that
it is properly connected. See
"Troubleshooting a CD Drive" in
"Troubleshooting Your System."
CPUs with different cache
sizes detected
Microprocessors with different cache
sizes are installed.
Ensure that all microprocessors have the
same cache size and that they are
properly installed. See "Processors" in
"Installing System Options."
Decreasing available
memory
Faulty or improperly installed memory
modules.
See "Troubleshooting System Memory"
in "Troubleshooting Your System."
Diskette drive
n seek
failure
Incorrect configuration settings in the
System Setup program.
Run the System Setup program to
correct the settings. See "Using the
System Setup Program" in the
User's
Guide.
Faulty or improperly installed diskette
drive.
See "Troubleshooting a Diskette Drive"
in "Troubleshooting Your System."
Diskette read failure
Faulty or improperly inserted diskette. Replace the diskette.
Diskette subsystem reset
failed
Faulty or improperly installed diskette
drive.
See "Troubleshooting a Diskette Drive"
in "Troubleshooting Your System."
Table 2-8.
System Messages (continued)
Message
Causes
Corrective Actions