Dell PowerEdge 1800 User Manual
Page 24

24
Indicators, Codes, and Messages
www
.dell.com | support.dell.com
Invalid NVRAM
configuration, resource
re-allocated
System configuration data has been
ignored.
Check the System Setup configuration
settings. See "Using the System Setup
Program" in the
User's Guide.
Invalid SCSI configuration
SCSI cable detected on
connector SCSIB of the
SCSI backplane, daughter
card not present
A SCSI cable is connected to the
channel B connector on the SCSI
backplane board; SCSI backplane
daughter card is not installed.
This message is not applicable to this
system.
Keyboard controller
failure
Faulty keyboard controller; faulty
system board.
Keyboard clock line
failure
Loose or improperly connected
keyboard cable; faulty keyboard; faulty
keyboard controller.
See "Troubleshooting the Keyboard" in
"Troubleshooting Your System."
Keyboard data line failure
Keyboard failure
Keyboard stuck key failure
Memory address line
failure at
address, read
value expecting value
Faulty or improperly installed memory
modules.
See "Troubleshooting System Memory"
in "Troubleshooting Your System."
Memory double word logic
failure at
address, read
value expecting value
Memory high address line
failure at
start address
to
end address
Memory high data line
failure at
start address
to
end address
Memory odd/even logic
failure at
start address
to
end address
Memory write/read failure
at
address, read value
expecting
value
Table 2-8.
System Messages (continued)
Message
Causes
Corrective Actions