Dell PowerEdge 1800 User Manual
Page 23

Indicators, Codes, and Messages
23
Error: Incorrect memory
configuration.
Swap the DIMMs in slots
DIMM1_A and DIMM1_B with
DIMMs in slots DIMM2_A and
DIMM2_B.
Memory slots DIMM1_A and
DIMM1_B must be populated with
dual-rank DIMMs if dual-rank
DIMMs are populated in the system.
Swap the memory modules in
DIMM1_A and DIMM1_B with the
memory modules in slots DIMM2_A
and DIMM2_B. See "General Memory
Module Installation Guidelines" in
"Installing System Components."
Error: Maximum PCI option
ROM count exceeded!
Too many expansion cards have ROM
enabled in the System Setup program.
Disable ROM for some of the expansion
cards. See "Using the System Setup
Program" in the
User's Guide.
Gate A20 failure
Faulty keyboard controller; faulty
system board.
Hard disk controller
failure
Incorrect configuration settings in
System Setup program; improperly
installed hard drive, or loose interface
or power cable; faulty hard-drive
controller subsystem.
Run the System Setup program to
correct the drive type. See "Using the
System Setup Program" in the
User's
Guide. If the problem persists, see
"Troubleshooting SCSI Hard Drives" and
"Troubleshooting SATA Hard Drives" in
"Troubleshooting Your System."
Hard disk read failure
I/O parity interrupt at
address
Faulty or improperly installed
expansion card.
See "Troubleshooting Expansion Cards"
in "Troubleshooting Your System."
Invalid configuration
information - please run
SETUP program
Incorrect configuration settings in
System Setup program;
NVRAM_CLR jumper is installed;
faulty system battery.
Check the System Setup configuration
settings. See "Using the System Setup
Program" in the
User's Guide. Remove
the NVRAM_CLR jumper. See
Figure A-2 for jumper location. If the
problem persists, see "Troubleshooting
the System Battery" in "Troubleshooting
Your System."
Table 2-8.
System Messages (continued)
Message
Causes
Corrective Actions