Control panel (optional), Installing the backplane, Removing the control panel – Dell PowerEdge C1100 User Manual
Page 91

Installing System Components
91
Installing the Backplane
1 Insert the backplane in the direction of the arrow until it is seated in the
system.
2 Replace all the hard drives in the system. See "Installing a Hard-Drive
3 Replace the cooling fan assembly and secure with the two screws.
4 Connect all cooling fan power cables.
5 Connect the SATA cables, the IPMB cable, and a single power cable.
See Figure 5-4.
6 Replace the cooling shroud. See "Installing the Cooling Shroud" on
7 Replace the system cover. See "Closing the System" on page 56.
8 Reconnect the system and peripherals to their electrical outlets,
and turn on the system.
Control Panel (Optional)
Removing the Control Panel
CAUTION:
Many repairs may only be done by a certified service technician.
You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.
1 Turn off the system, including any attached peripherals, and disconnect
the system from the electrical outlet.
2 Remove the single securing screw from the side of the chassis.
See Figure 3-24.
3 Pull the control panel out of the chassis. See Figure 3-24.
book.book Page 91 Tuesday, February 26, 2013 11:33 AM