BMC LAN Configuration
QPI Error Logging
(Enabled default)
Enable or disable IOH QPI 0/1 error.
IOH Internal Error
Logging (Enabled
default)
Enable or disable IOH Internal error logging.
NMI on Error
(Fatal default)
Enable to set the state of NMI on Error:
• Fatal: Fatal error issue NMI.
• Uncorrectable: Fatal and Uncorrectable errors issue
NMI.
• Correctable: Issues NMI on all errors.
Option
Description
Channel Number
Displays channel number of BMC.
Channel Number Status
(01 default)
Displays channel number status of BMC.
BMC LAN Port
Configuration
(Shared-NIC default)
Select the BMC LAN Port Configuration type.
DHCP Enabled
(Disabled default)
Enables or disables the BMC get the LAN IP from
a DHCP server.
IP Address
Enter an IP address in decimal in the form of
XXX.XXX.XXX.XXX (XXX less than 256 and
in decimal only).
Subnet Mask
Enter a Subnet Mask in decimal in the form of
XXX.XXX.XXX.XXX (XXX less than 256 and
in decimal only).
Gateway Address
Enter Gateway Address in decimal in the form of
XXX.XXX.XXX.XXX (XXX less than 256 and
in decimal only).
Current MAC Address in
BMC
Displays the MAC address of BMC.
Option