beautypg.com

Bmc lan configuration – Dell PowerEdge C1100 User Manual

Page 45

background image

Using the System Setup Program

45

BMC LAN Configuration

QPI Error Logging

(Enabled default)

Enable or disable IOH QPI 0/1 error.

IOH Internal Error

Logging (Enabled

default)

Enable or disable IOH Internal error logging.

NMI on Error

(Fatal default)

Enable to set the state of NMI on Error:

• Fatal: Fatal error issue NMI.
• Uncorrectable: Fatal and Uncorrectable errors issue

NMI.

• Correctable: Issues NMI on all errors.

Option

Description

Channel Number

Displays channel number of BMC.

Channel Number Status

(01 default)

Displays channel number status of BMC.

BMC LAN Port

Configuration

(Shared-NIC default)

Select the BMC LAN Port Configuration type.

DHCP Enabled

(Disabled default)

Enables or disables the BMC get the LAN IP from

a DHCP server.

IP Address

Enter an IP address in decimal in the form of

XXX.XXX.XXX.XXX (XXX less than 256 and

in decimal only).

Subnet Mask

Enter a Subnet Mask in decimal in the form of

XXX.XXX.XXX.XXX (XXX less than 256 and

in decimal only).

Gateway Address

Enter Gateway Address in decimal in the form of

XXX.XXX.XXX.XXX (XXX less than 256 and

in decimal only).

Current MAC Address in

BMC

Displays the MAC address of BMC.

Option

Description