Dell PowerEdge C1100 User Manual
Page 26

26
About Your System
0082
Yes
Secondary Master
Drive - ATAPI
Incompatible
See "Troubleshooting a Hard Drive" on
0083
Yes
Secondary Slave
Drive - ATAPI
Incompatible
See "Troubleshooting a Hard Drive" on
0101
Yes
Warning! This
system board does
not support the
power requirements
of the installed
processor. The
processor will be run
at a reduced
frequency, which will
impact system
performance.
Ensure that your processors match and
conform to the type described in the
processor technical specifications
outlined in your system’s Getting Started
Guide.
See "Troubleshooting Processors" on
0102
Yes
Error! The CPU
Core to Bus ratio or
VID configuration
has failed! Please
enter BIOS Setup
and re-config it.
The message is displayed on the screen,
an error is logged to the SEL, and user
input is required to continue. The user
can take immediate corrective action or
choose to continue booting.
0120
Yes
Thermal Failure
detected by
PROCHOT#.
Ensure that the processor heat sinks are
properly installed.
See "Troubleshooting Processors" on
page 112 and "Troubleshooting System
Cooling Problems" on page 106.
0121
Yes
Thermal Failure
detected by
PROCHOT#.
Ensure that the processor heat sinks are
properly installed.
See "Troubleshooting Processors" on
page 112 and "Troubleshooting System
Cooling Problems" on page 106.
Code
Log in BMC Error Message
Corrective Action