beautypg.com

Dell PowerEdge R905 User Manual

Page 42

background image

42

About Your System

Warning: Following

faulty DIMMs are

disabled:

CPU

n: DIMM n

CPU

n: DIMM n

Total memory size

is reduced.

Faulty or improperly
seated memory module(s)
used by CPUn.

See "Troubleshooting
System Memory" on
page 158.

Warning! No

microcode update

loaded for

processor

n

Microcode update failed. Update the BIOS firmware.

If the problem persists, see
"Getting Help" on
page 181.

Warning: One or

more faulty DIMMs

found on CPUn

Faulty or improperly
seated memory module(s)
used by CPUn.

See "Troubleshooting
System Memory" on
page 158.

Warning: The

installed memory

configuration is

not optimal. For

more information

on valid memory

configurations,

please see the

system

documentation on

the technical

support web site.

Invalid memory
configuration. The system
will run but with reduced
functionality.

Ensure that the memory
modules are installed in a
valid configuration. See
"General Memory Module
Installation Guidelines" on
page 94. If the problem
persists, see
"Troubleshooting System
Memory" on page 158.

Write fault

Write fault on

selected drive

Faulty optical drive, hard
drive, or hard-drive
subsystem.

See "Troubleshooting an
Optical Drive" on page 160
or "Troubleshooting a Hard
Drive" on page 161.

NOTE:

For the full name of an abbreviation or acronym used in this table, see

"Glossary" on page 183.

Table 1-8.

System Messages (continued)

Message

Causes

Corrective Actions