Dell PowerEdge R905 User Manual

Page 40

background image

40

About Your System

Remote

configuration

update attempt

failed

System unable to process
Remote Configuration
request.

Retry Remote
Configuration.

ROM bad checksum =

address

An expansion card is
improperly installed or is
faulty.

Reseat the expansion cards.
Ensure that all appropriate
cables are securely
connected to the expansion
cards. If the problem
persists, see
"Troubleshooting
Expansion Cards" on
page 166.

Sector not found

Seek error

Seek operation

failed

Faulty hard drive.

See "Troubleshooting a
Hard Drive" on page 161.

Shutdown failure

Shutdown test failure.

See "Troubleshooting
System Memory" on
page 158.

The amount of

system memory has

changed

Memory has been added
or removed or a memory
module may be faulty.

If memory has been added
or removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to
determine if single-bit or
multi-bit errors were
detected and replace the
faulty memory module. See
"Troubleshooting System
Memory" on page 158.

Table 1-8.

System Messages (continued)

Message

Causes

Corrective Actions