Dell PowerEdge R905 User Manual
Page 26
26
About Your System
E161C
PS # Input
Lost
Power source for specified
power supply is
unavailable, or out of
acceptable range.
Check the AC power
source for the specified
power supply. If problem
persists, see
"Troubleshooting Power
Supplies" on page 156.
E1620
PS # Input
Range
Power source for specified
power supply is
unavailable, or out of
acceptable range.
Check the AC power
source for the specified
power supply. If problem
persists, see
"Troubleshooting Power
Supplies" on page 156.
E1624
PS
Redundancy
Power supply redundancy
has been lost. If the
remaining power supply
fails the system will shut
down.
See "Troubleshooting
Power Supplies" on
page 156.
E1625
PS AC
Current
Power source is out of
acceptable range.
Check the AC power
source.
E1710
I/O Channel
Chk
The system BIOS has
reported an I/O channel
check error.
See "Getting Help" on
page 181.
E1711
PCI PERR B##
D## F##
PCI PERR
Slot #
The system BIOS has
reported a PCI parity
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.
The system BIOS has
reported a PCI parity
error on a component
that resides in PCI slot #.
Remove and reseat the
specified PCI expansion
card. If the problem
persists, see
"Troubleshooting
Expansion Cards" on
page 166. If
troubleshooting does not
resolve the problem, see
"Getting Help" on
page 181.
Table 1-7.
LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes
Corrective Actions