beautypg.com

Dell PowerEdge R905 User Manual

Page 26

background image

26

About Your System

E161C

PS # Input

Lost

Power source for specified
power supply is
unavailable, or out of
acceptable range.

Check the AC power
source for the specified
power supply. If problem
persists, see
"Troubleshooting Power
Supplies" on page 156.

E1620

PS # Input

Range

Power source for specified
power supply is
unavailable, or out of
acceptable range.

Check the AC power
source for the specified
power supply. If problem
persists, see
"Troubleshooting Power
Supplies" on page 156.

E1624

PS

Redundancy

Power supply redundancy
has been lost. If the
remaining power supply
fails the system will shut
down.

See "Troubleshooting
Power Supplies" on
page 156.

E1625

PS AC

Current

Power source is out of
acceptable range.

Check the AC power
source.

E1710

I/O Channel

Chk

The system BIOS has
reported an I/O channel
check error.

See "Getting Help" on
page 181.

E1711

PCI PERR B##

D## F##

PCI PERR

Slot #

The system BIOS has
reported a PCI parity
error on a component
that resides in PCI
configuration space at
bus ##, device ##,
function ##.

The system BIOS has
reported a PCI parity
error on a component
that resides in PCI slot #.

Remove and reseat the
specified PCI expansion
card. If the problem
persists, see
"Troubleshooting
Expansion Cards" on
page 166. If
troubleshooting does not
resolve the problem, see
"Getting Help" on
page 181.

Table 1-7.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions