Table 1-7.
LCD Status Messages
Line 1
Message
Line 2
Message
Causes
Corrective Actions
N/A
SYSTEM NAME
A 62-character string that
can be defined by the user
in the System Setup
program.
The SYSTEM NAME
displays under the
following conditions:
• The system is powered
on.
• The power is off and
active POST errors are
displayed.
This message is for
information only.
You can change the
system string in the
System Setup program.
See "Using the System
Setup Program" on
page 45.
E1000
FAILSAFE,
Call Support
See "Getting Help" on
page 181.
E1114
Temp Ambient
Ambient system
temperature is out of
acceptable range.
See "Troubleshooting
System Cooling
Problems" on page 157.
E1210
CMOS Batt
CMOS battery is missing,
or the voltage is out of
acceptable range.
See "Troubleshooting the
System Battery" on
page 155.
E1211
ROMB Batt
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery.
See "Installing the SAS
RAID Controller Card
Battery" on page 115, and
"Troubleshooting System
Cooling Problems" on
page 157.
E12
nn
# PwrGd
Specified voltage
regulator has failed.
See "Getting Help" on
page 181.
E1229
CPU # VCORE
Processor # VCORE
voltage regulator has
failed.