Dell PowerEdge R905 User Manual
Page 24

24
About Your System
E1313
Fan
Redundancy
One or more cooling fans
has failed. Cooling fan
redundancy has been lost.
See "Troubleshooting
System Cooling
Problems" on page 157.
E1414
CPU #
Thermtrip
Specified microprocessor
is out of acceptable
temperature range and
has halted operation.
See "Troubleshooting
System Cooling
Problems" on page 157. If
the problem persists,
ensure that the
microprocessor heat sinks
are properly installed. See
"Troubleshooting the
Microprocessors" on
page 167.
NOTE:
The LCD continues
to display this message
until the system’s power
cord is disconnected and
reconnected to the AC
power source, or the SEL
is cleared using either
Server Assistant or the
BMC Management Utility.
See the Dell OpenManage
Baseboard Management
Controller User’s Guide for
information about these
utilities.
E1418
CPU #
Presence
Specified processor is
missing or bad, or the
system is in an
unsupported
configuration.
See "Troubleshooting the
Microprocessors" on
page 167.
Table 1-7.
LCD Status Messages (continued)
Line 1
Message
Line 2
Message
Causes
Corrective Actions