beautypg.com

Replacing a peripheral interposer board, Fan interposer board, Removing a fan interposer board – Dell PowerEdge R905 User Manual

Page 131

background image

Installing System Components

131

c

Lift the board out of the system, being careful to avoid damaging
components on the face of the board.

d

Place the interposer board aside on a work surface.

Replacing a Peripheral Interposer Board

1 Install the peripheral interposer board:

a

Carefully lower the interposer board into the system, being careful to
avoid damaging components on the face of the board. See Figure 3-31.

b

Align the installation alignment slot on the bottom of the interposer
board with the alignment pin on the bottom of the chassis.

c

Slide the retention slots on the interposer board over the retention
hooks on the chassis.

d

Slide the board downward until the blue retention tab snaps into
place.

2 Connect the SATA, planar interface, and control panel cables to the back

of the interposer board. See Figure 3-31.

3 Connect the power cable to the top of the interposer board.
4 Reconnect the SAS and backplane power cables to the back of the SAS

backplane. See Figure 3-29 or Figure 3-30.

5 Replace the cooling shroud assembly. See "Replacing the Cooling Shroud

Assembly" on page 72.

6 Replace the PEM. See "Replacing the PEM or PEM Shell" on page 78.
7 Close the system. See "Closing the System" on page 68.
8 Reconnect the system to its electrical outlet and turn the system on,

including any attached peripherals.

Fan Interposer Board

Removing a Fan Interposer Board

CAUTION:

Many repairs may only be done by a certified service technician. You

should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by the online or telephone service and