beautypg.com

Dell PowerEdge R905 User Manual

Page 30

background image

30

About Your System

E201F

DRAC Config

Remote access controller
(RAC) configuration
failure.

Check screen for specific
error messages. Ensure
that the RAC card and
cables are properly seated.
See "RAC Card" on
page 86. If problem
persists, see your RAC
documentation.

E2020

CPU Config

CPU configuration
failure.

Check screen for specific
error messages.

E2021

Memory

Population

Incorrect memory
configuration. Memory
population order
incorrect.

Check screen for specific
error messages. See
"Troubleshooting System
Memory" on page 158.

E2022

POST Fail

General failure after
video.

Check screen for specific
error messages.

E2110

MBE DIMM ##

& ##

One of the DIMMs in the
set implicated by "## &
##" has had a memory
multi-bit error (MBE).

See "Troubleshooting
System Memory" on
page 158.

E2111

SBE Log

Disable DIMM

##

The system BIOS has
disabled memory single-
bit error (SBE) logging,
and will not resume
logging further SBEs until
the system is rebooted.
"##" represents the
DIMM implicated by the
BIOS.

See "Troubleshooting
System Memory" on
page 158.

Table 1-7.

LCD Status Messages (continued)

Line 1
Message

Line 2
Message

Causes

Corrective Actions